Quick Details

  • Place of Origin: Zhejiang, China (Mainland)
  • Brand Name: SUPOWER
  • Model Number: SPP2000-12-C
  • Output Power: 2000W
  • Output Type: Single
  • Size: 405*169*86mm
  • Weight: 5.1KGS
  • Input Voltage: 12VDC (optional)
  • Output Voltage: 120V/220V AC (optional)
  • Type: DC AC Inverter
  • Output Frequency: 50/ 60Hz
  • Output Current: 9.1A/16.6A
  • Efficiency: 94%
  • Charge code: 3 Stages (CC, CV, FC)
  • Plug for Charging: EUR/USA/AUS/Univesal type (optional)
  • USB output: 5V 1500mA
  • Case color: Orange
  • Certificate: RoHS, CE, FC
  • Warranty: 2 Years

Packaging & Delivery

Packaging Details 1PC/CTN
Delivery Time 7 days

High efficiency 2000W peak power 4000W 12V 220V UPS Pure Sine Wave Power Inverter with Battery Charger 

 

SUPOWER with charge power inverter, have Switch and battery charger function, with charge inverter connection the grid to backup and charge the battery. Transfer time <9MS. Pure sine wave inverter, with charge inverter current 12V 20A/24V 10A/48V 5A.we support Default Grid priority or inverter priority.

 1.The pure sine wave inverter charger support Optional Grid  Default Grid priority or inverter priority.
 2.The inverter and Grid Transfer time <=9MS
 3.12V20A/24V10A/48V5A,CC CV CF Three stages Automatic charge
 4.High frequency combinatorial circuit technology
 5.Performance related fan control
 6.Accurate and stable sine through analogue technique
 7.High efficiency <=94%
 8.Protection against reverse polarity and short-circuit
 9.Auto-restart-function
 10.Switch off at too high temperature
 11.Deep discharge protection for battery
 12.Under and upper voltage control
 13.Overload protection

 

SUPOWER 2000w inverter charger,2000w charge inverter transfer time is < 9MS. CNBOU 2000w inverter charger,2000w charge inverter has a prefect and powerful protection(2000w charger inverters low voltage alarm, low/over voltage shut down, low/over voltage recovery.).

 

Parameter:

Model

 SPP2000-12-1C

SPP2000-24-1C

SPP2000-48-1C

SPP2000-12-2C

SPP2000-24-2C

SPP2000-48-2C

Continuous Power

2000W

Surge Power

4000W

Frequency

50HZ±0.5HZ or    60HZ±0.5HZ

Wave Form

Pure Sine Wave

AC Regulation

THD<3%( Linear    Load)

USB Outlet

5V 500MA

Output Efficiency

Highest 94%

DC Voltage

 DC12V

DC24V

DC48V

DC12V

DC24V

DC48V

AC Voltage

100VAC or 110VAC OR 120VAC ±5%

220VAC or 230VAC or 240VAC ±5%

No Load Current Draw

 1.4A

0.8A

0.3A

1.4A

0.8A

0.3A

DC Voltage Range

10-15.5V

20-31V

40-61V

10-15.5V

20-31V

40-61V

Low Voltage Alarm

10.5±0.5V

21±0.5V

42±1V

10.5±0.5V

21±0.5V

42±1V

Low Voltage Shut Down

10±0.5V

20±0.5V

40±1V

10±0.5V

20±0.5V

40±1V

Over Voltage Shut Down

15.5±0.5V

31±0.5V

61±1V

15.5±0.5V

31±0.5V

61±1V

Low Voltage Recovery

13±0.5V

24±0.5V

48±1V

13±0.5V

24±0.5V

48±1V

Over Voltage Recovery

14.8V±0.5V

29V±0.5V

59V±1V

14.8V±0.5V

29V±0.5V

59V±1V

Charging Voltage

14.6V±0.2V

29.2V±0.3V

58.4V±0.5V

14.6V±0.2V

29.2V±0.3V

58.4V±0.5V

Floating Charge Voltage

13.8V±0.2V

27.6V±0.3V

55V±0.5V

13.8V±0.2V

27.6V±0.3V

55V±0.5V

Charging Current

≤15A

≤8A

≤5A

≤15A

≤8A

≤5A

Transfer Time

≤9MS

≤9MS

≤9MS

≤9MS

≤9MS

≤9MS

Grid Input Draw

100VAC or 110VAC OR 120VAC ±10% 

220VAC or 230VAC or 240VAC ±10%

Priority

Optional/Default Grid Priority.

Protection

Low Voltage/Over Voltage

LED Alarm and Automatic Recovery.

Overload

LED Alarm and Automatic Recovery.

Over Temperature

LED Alarm and Automatic Recovery.

Short Circuit

LED Alarm and Automatic Recovery.

Input Oppose

Diode or MOS FET

Working Temperature

-10°- +50°

Qty/Carton

1PC

Storage Temperature

-30°- +70°

Carton Size

600*250*180(mm)

Production Size

 455*169*86(mm)

Carton Weight

  6.6(kg)

Package Size

600*250*180(mm)

Warranty

2 Years

N.W/G.W

4.75/6.6(kg)

Configuration

Standard

Start

Bipolar soft-start

Cooling Way

Intelligent Cooling Fan

 

 

 

 

About US

 

 

About Packing

 

 

FAQ

How to choose a suitable inverter?

If your load is resistive loads, such as: bulbs, you can choose a modified wave inverter. But if it is inductive loads and capacitive loads, we recommend using pure sine wave inverter. For example: fans, precision instruments, air conditioner, fridge, coffee machine, computer, and so on. Modified wave can be started with some inductive loads, but effect for load using life, because capacitive loads and inductive loads need high quality power.

 

How do I choose the size of the inverter?

Different types of load demand for power are different. You can view the load power values to determine the size of the inverter.

Notice: resistive load: you can choose the same power as the load.

Capacitive loads: according to the load, you can choose 2-5 times power.

Inductive loads: according to the load, you can choose 4-7 times power.

 

How connection between batteries and an inverter?

We usually believe that cables connecting battery terminal to inverter shorter is better. If you are just standard cable should be less than 0.5M, but should correspond to the polarity of the batteries and inverter-side outside. If you want to lengthen the distance between battery and inverter, please contact us and we will calculate the recommended cable size and length. Due to long distances using a cable connection, there will be a reduced voltage, which means that the inverter voltage would be far below the battery terminal voltage, this inverter will appear under voltage alarm conditions.

 

How to calculate the load of working hours requires configuration of the battery size?

We will usually have a formula to calculate, but it is not hundred percent accurate, because there is also the battery's condition, the old batteries have some loss, so this is only a reference value:

Work hours = battery capacity * battery voltage *0.8/load power (H= AH*V*0.8/W)

 

How to choose a solar controller?

At present, solar controller have MPPT and PWM. According to our actual test data, conversion efficiency of the PWM controller normally less than 70%, MPPT controller conversion efficiency is about 95-97%. MPPT solar controller is expensive than PWN solar controller, but the price of solar module are more expensive. Using MPPT controller, you can reduce the solar module, save the cost of the entire system

 

How to choose a suitable MPPT solar charge controller?

SUPOWER MPPT solar controller support PV input voltage 18V-150V, DC 12V 24V is automatic identification. You just need according to battery capacity to select different charging current controller.

 

 

Contact me

 

Transaction History of the Supplier

Below is the information about the supplier's transactions conducted via Alibaba.com. If you require further details regarding the transaction data, please contact the supplier directly.

Transaction Overview

Transactions

Transaction Details

This supplier has completedtransactions with buyers from .

Shipping Destination
Transaction Value
Transaction Date
Email to this supplier
Trade Assurance
China (Mainland) | Trading Company
Transaction Level:
Supplier Assessments:
20 Transactions 60,000+
The supplier’s transactions conduted via Alibaba.com in the past 6 months.
The supplier supports Trade Assurance – A free service that protects your orders from payment to delivery.
Supplier's Trade Assurance Limit: US $39,000
Learn More